E11Q is an RG11 75 Ohm quad-shield coaxial cable for Free to Air and Pay TV systems. It's approved for both Foxtel satellite and Telstra cable networks. Available in 305m reels with meter marking, E11Q is suited for longer cable backbone and lateral runs where lengths are high loss with RG6. E11Q is a 3GHz rated low loss coaxial cable with a copper-clad steel centre conductor for durability and four shielding layers to guarantee maximum signal protection and stability.
View More Coaxial Cable
Inner: 1 reel of 305 metres
Bulk: 1 pallet of 27 reels (8,235 metres)
Construction | ||
---|---|---|
Inner Conductor | Material | Copper Clad Steel Wire |
Diameter, mm | 1.63±0.015 | |
Insulation | Material | Physically Foamed PE |
Diameter, mm | 7.11±0.15 | |
Outer Conductor | 1st shield | Bonded Al/PET/Al Tape 7.32 ±0.15 |
2nd shield | Al-Mg Alloy Wire Braid | |
3rd shield | Non-bonded Al/PET/Al Tape | |
4th shield | Al-Mg Alloy Wire Braid | |
Jacket | Material | FR PVC |
Diameter, mm | 10.34±0.20 | |
Mechanical Properties | ||
Bending Radius, mm | Single | 50 |
Typical | 100 | |
Pulling Strength, N | 384 | |
Adhesion Force, N | >60 | |
Electrical Properties | ||
Impedance, Ω | 75±3 | |
DCR of Inner conductor, Ω /km | 40.40 | |
DCR of outer conductor, Ω /km | 14.40 | |
Capacitance, pF/m | 54 | |
Propagation Velocity, % | 82 | |
DC Breakdown Voltage, kV | 6.0 | |
Insulation Resistance, MΩ•km | >1×104 | |
Screening Attenuation, dB | >105@5~1000MHz | |
>95@1000~2000MHz | ||
>85@2000~3000MHz | ||
Attenuation | ||
Frequency MHz | Max. attenuation @20℃,dB/100m | |
5MHz | 1.25 | |
55MHz | 3.15 | |
211MHz | 6.23 | |
250MHz | 6.72 | |
270MHz | 7.00 | |
300MHz | 7.38 | |
330MHz | 7.71 | |
350MHz | 7.94 | |
400MHz | 8.53 | |
450MHz | 9.02 | |
500MHz | 9.51 | |
550MHz | 9.97 | |
600MHz | 10.43 | |
750MHz | 11.97 | |
870MHz | 13.31 | |
1000MHz | 14.27 | |
1300MHz | 16.21 | |
1450MHz | 17.36 | |
1750MHz | 19.52 | |
2150MHz | 21.65 | |
2600MHz | 24.04 | |
2832MHz | 25.09 | |
3000MHz | 25.86 | |
Return Loss, dB | ||
5-3000MHz | ≥20 | |
Standards | ||
Operation | -40~+70°C | |
UL 1581 UV Resistance 720h | Compliant | |
2011/65/EU | Compliant |